Error messages whirlpools on the control panel

chabové hlášky

New product

Chybové hlášky vířivky na ovladacím panelu Expand

0 Kč tax excl.

Error massage spas and hot tubs mean what? Codes: h2>

p>

ACC (Applied Computer Controls) Spas hot tubs strong> p>

COLD strong> = Temperature in the spa heater housing is below 40 _ F. Status of the heater element is unknown. The low speed pump or pump circ Will Operate Continuously until the temperature rises above 45 _ F.
OH strong> = Over heat. The spa is at a temperature above 108 degrees. Do not use spa When temperature is flashing or the OH message is Displayed.
hawthorn strong> = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112 _ F.
Seop strong> = Sensor open or disconnected. Heater disabled but the spa is operational.
Sesha strong> = Sensor short, nonfunctional. Heater disabled but the spa is operational.
PSoC strong> = Spa ressure switch open with circulating pumps.
PSOL strong> = Spa open pressure switch with low pumps.
PSoH strong> = Pressure switch open with high pumps.
Toe strong> = Time out error. Rare system error. Spa unusable. Contact ACC. P>

Balboa strong> (Used by Idol and many other Spas hot tubs) p>

pd strong> = Power supply, unit running on battery backup
OH strong> Sensors reading = 112-118 _ F.
OHH < / strong> = Overheat. Spa has shut down. One sensor has detected 118 _ Fat heater.
OHS strong> = Overheat. Spa has shut down. One sensor has detected 110 _ F. Span>
Flo strong> = Improper flow or pressure switch malfunction
Cool strong> Water temp = 20 _ below set point
ICE strong> = Potential freeze condition has been detected
SN1 strong> = Hi-limit sensor malfunction
Sn3 strong> = Temp sensor malfunction
SNA strong> = Spa is shut down. Sensor plugged into jack A is not working.
Snb strong> = Spa is shut down. Sensor plugged into jack B is not working.
SnS strong> = Sensors out of balance. If alternating with temp, May be temporary condition. If the display shows only this message (blinking), the spa is shut down.
HFL strong> = Substantial Difference Between temperature sensors detected. Could Indicate a flow problem.
LF strong> = Persistent low flow problems. (Displays on the 5th of Occurrence "HFL" message with 24 hours). Heater is shut down, but other spa functions run normally.
Dr strong> = Inadequate water detected in heater.
dry strong> = Inadequate water detected in heater. (Displays on third Occurrence of "dr" message). Spa is shut down.
Pr strong> = When the spa is first Actuated, it will go into Priming mode.
iLOC strong> = Interlock failure - Possible pump or ozone spike.
(---) strong> = Unknown water temperature. (Displays When first powered up after refill).
Std strong> = Spa operating in Standard Mode.
ECN strong> = Spa operating in Economy Mode.
strong> = Spa operating in Standard-in-Economy Mode. p>

Brett Aqualine strong> p>

OH strong> = Temp exceeds 118 _ F
FR strong> = Freeze condition - temp below 40 _ F
FL strong> = Pressure switch failure
EO strong> = Shorted temp sensor
E1 strong> Open = temp sensor
E2 < / strong> = Shorted hi-limit sensor
E3 strong> = Open hi-limit sensor
E4 strong> = Shorted flow switch
E7 strong> = Improper electrical connection p>

CTI strong> p>

Th1 / 39 strong> = On startup indicates temperature probe problem.
Th2 / current temperature strong> = On startup indicates temperature probe problem. < br /> Th3 / 39 strong> = On startup indicates water temperature less than 39 _ F.
OH strong> = Overheating, water over 112 _ F. When the System will restart temp. drops.
hot strong> = Overheating, water over 112 _ F. System will restart When temp. drops.
Voice strong> = High limit switch tripped. p>

Dream Maker Hot Tubs strong> p>

OH strong> Overheat = 108 _ F, the spa is deactivated. Do not enter the water.
FL strong> = Flow. Pressure switch is not working.
SN strong> = Non-functional high temperature sensor. Heater is deactivated.
F2 strong> = 4 hours daily filtration
F4 strong> = 8 hours daily filtration
F6 strong> = 12 hours daily filtration
FC strong> = continuous filtration p>

EasyPak strong> p>

C strong> = Celsius
CL strong> = Current Time of Day
ECdu strong> = Economy Mode duration
Econ strong> = Economy Mode Turn On
F strong> = Fahrenheit
Fldu strong> = Filter Cycle duration
Flon strong> = Filter Cycle Turn On
FLC strong> = Pressure Switch Alarm
FLO strong> = Pressure Switch Alarm
FREE strong> = Freeze Protection Alarm
Voice strong> = High Temperature Alarm
Loc strong> = Panel / Keypad Locked
PRH strong> = Temperature Sensors Alarm
Whoa strong> = Temperature Sensors Alarm
Here strong> = Temperature Set Celsius
Here strong> = Fahrenheit Temperature Set p>

Gecko Used in spas and other Idol strong> p>

FLO strong> = Pressure switch failure, switch open
FLC strong> = Pressure switch failure, switch closed
Whoa strong> = Temp sensor failure
PRH strong> = Hi-limit sensor failure
Voice strong> = Sensor measuring 119 _ F
FrE strong> = Possible freeze condition detected p>

Hercules spas strong> p>

OH strong> Spa = temp exceeds Acceptable limits
FLO strong> = Flow problem
ICE strong> = Freeze condition detected
SN1 strong> = Hi-limit sensor failure
SN2 strong> = Temp sensor failure p>

Hurricane spas strong> p>

PS strong> = Flow or pressure switch failure
SH strong> = Shorted sensor
OP strong> = Open Sensor
LO strong> = temp below 60 _ F - freeze
Voice strong> = temp above 118 _ F p>

Hydro-Quip spas strong> p>

C strong> = Celsius
CL strong> = Current Time of Day
ECdu strong> = Economy Mode duration
Econ strong> = Economy Mode Turn On
F strong> = Fahrenheit
Fldu strong> = Filter Cycle duration
Flon strong> = Filter Cycle Turn On
FLC strong> = Pressure Switch Alarm
FLO strong> = Pressure Switch Alarm
FREE strong> = Freeze Protection Alarm
Voice strong> = High Temperature Alarm
Loc strong> = Panel / Keypad Locked
PRH strong> = Temperature Sensors Alarm
Whoa strong> = Temperature Sensors Alarm
Here strong> = Temperature Set Celsius
Here strong> = Fahrenheit Temperature Set p>

p>

Jacuzzi Whirlpool spas strong> p>

OH strong> = Overheat Protection (Heater is deactivated, pumps low speed is activated).
Cool strong> = Spa water is more Than 20 _ F cooler Than the temperature set point.
FLO * strong> = Flow Switch (Heater is deactivated. Pump May Also be deactivated).
Hold strong> = Panel sensors have been pressed too many times in a short period of time.
HOT strong> = Circuit Board temperature has exceeded Acceptable limit. < br /> ICE strong> = Freeze protection. No action is necessary.
I CE2 strong> = Freeze protection. No action is necessary.
PNL strong> = Communication Between the panel and circuit board is faulty.
---- strong> = "Watchdog" (with spa deactivated) A problem has been detected.
SN1 strong> = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated).
Sn3 strong> = Open or shorted sensor (heater disabled).
FLO2 strong> = Closed or shorted flow switch on system startup p>

Pinnacle strong> p>

OH strong> = Temperature has exceeded 110 _ F
SN strong> = Sensor failure
FL strong> = Flow / pressure switch stuck in the closed position p>

Spa Builders spas strong> p>

SN1 strong> = nonfunctional high temperature sensor. Heater is deactivated.
SN2 strong> = nonfunctional temperature sensor. Heater is deactivated.
FL1 strong> = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ENSURE pump is primed. Check for clogged filter.
FL2 strong> = Pressure switch problem. Switch closed while pump is deactivated.
COL strong> = Cool condition. If water temperature drops 20 _ F below the set temperature, low speed pump and heater activates to bring within The temperature of 15 _ set temperature.
ICE strong> = Freeze condition. 55 _ F detected. Low speed pump and heater will activate until spa Reaches 65 _ F.
OH strong> = High temperature condition, Has Reached 110 _ F. Do not enter the spa. Low speed pump (air blower and if so equipped) will activate to assist in Lowering temperature.
--- strong> = "Watchdog". Water temperature has Reached 118 _ F. Entire system is disabled. Contact Qualified service technician. Span> p>

Sundance Spas strong> p>

iLOC strong> = Interlock failure - Possible pump or ozone spike
FLO strong> = Pressure switch Flow switch malfunction or malfunction (system specific) < br /> Hold strong> = panel buttons pressed it many times it Quickly
HOT strong> = PCB temperature above Acceptable limit - air blower on
ICE strong> = Potential freeze condition
PNL strong> = Communication Between the PCB panel and interrupted
SN1 strong> = Hi-limit sensor failure
< strong> Sn3 strong> = Temp sensor failure
---- strong> = "Watchdog" (spa is deactivated) A problem has been detected p>

Vita Spas strong> p>

Hilite strong> Water temp = Acceptable limit over
BJ2P strong> = Pump / Blower purge - normal condition
FP strong> = Freeze protect temp-unders Acceptable condition
SS = 0; SS = S; LS = O; LS = S strong> = Multiple Causes; open sensors, bad connection to the panel, improper voltage, etc. p>